5402 Tower Rd
Tallahassee, FL 32303
850-562-3132

Local Reviews
for saint teresa, fl

Rated 4.9 out of 5 stars based on 15 customer reviews

Love this company

Always excellent service. Jeremy is a fine young man, very considerate and does a wonderful job!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent service always!

A fine young man - so thankful that he has my account!


Response from Benson's Heating and Air Conditioning:

Thank you so much for this great 5-star review. We really appreciate your business and helping to share the word about us.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great

Aiden did great - very courteous, professional and efficient. The survey didn't work for me.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Review

I pay $400 a year for a support agreement that used to include replacing filters twice a year now you don’t include that but yet you still charge me $400 not cool


Response from Benson's Heating and Air Conditioning:

We appreciate the positive rating.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Terrific service

Very prompt , professional, courteous and efficient.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Service


Response from Benson's Heating and Air Conditioning:

Thank you so much for taking the time to leave us a 5 star rating - it's much appreciated!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Gr8 service


Response from Benson's Heating and Air Conditioning:

Thank you so much for taking the time to leave us a 5-star review!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Grt service

  • Overall Experience
  • Quality
  • Price
  • Convenience

Terrific service

Ray did an excellent job - very thorough and very professional

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great Service

Was able to move my appt up which was a big help!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service, very helpful.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great Service

Annual Service: Tech arrive on schedule and service was done efficiently.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great Service

  • Overall Experience
  • Quality
  • Price
  • Convenience

Ac surge protectors

  • Overall Experience
  • Quality
  • Price
  • Convenience

great service

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations
for saint teresa, fl

Bryce D.

Bryce D. Job Checkin

Today I arrived on site and performed a summer time maintenance on your HVAC equipment. **Indoor Unit (Attic Air Handler):** * Replaced the Respicare filter with a spare the customer provided. * Confirmed the indoor coil is clean and in fair condition. **Outdoor Unit (Side of House Heat Pump):** * Verified the outdoor coil is clean and in fair condition. * Tested and confirmed the following electrical components are working properly: * Blower Motor * Condenser Fan Motor * Compressor * Compressor Run Capacitor * Fan Run Capacitor * Contactor * Electrical Wiring * Inspected and confirmed the following components are in good condition: * Blower Wheel * Primary Drain Pan * Electrical Wires Secured **System Performance:** * Cleared the condensate drain line and cleaned out the primary pan. * Tested the safety switch. * Measured a return air temperature of 80.0°F and a supply air temperature of 59.9°F. **Addit


Jeremy  B.

Jeremy B. Job Checkin

Today I performed a routine maintenance on your heat pump split system. I checked all electrical connections on both indoor and outdoor equipment, changed your air filters, flushed your drain line, checked your capacitor, ratings, and tested your system operations after the maintenance. Your system is operating properly at this time. I also left your box of filters in the laundry room.


Bryce D.

Bryce D. Job Checkin

Today I arrived on site and performed a summer time maintenance on your HVAC equipment. **Indoor Unit (Air Handler):** * Observed the indoor unit in fair condition, located in the closet. * Replaced the pleated 1" filter (16x20x1) with a spare provided by the customer. * Confirmed the indoor coil was clean and in fair condition. **Outdoor Unit (Heat Pump):** * Observed the outdoor unit in fair condition, located on the side of the house. * Confirmed the outdoor coil was clean and in fair condition. **Electrical Components:** * Tested and confirmed the blower motor, condenser fan motor, compressor, compressor run capacitor, fan run capacitor, contactor, and electrical wiring are operating within manufacturer specifications. **System Components:** * Inspected and confirmed the blower wheel, primary drain pan, and electrical wires are secured and in good working condition. **Measurements & Adjustments:** * Recorded a return air temperature of 74.0°F and a supply


Bryce D.

Bryce D. Job Checkin

Today I arrived on site and performed a summer time maintenance on your HVAC equipment. **Air Handler (Attic):** * Replaced the air filters with the customer's spare pleated 20x20x4 and 16x18x2 filters. * Confirmed the indoor coil is in fair and clean condition. **Heat Pump (Side of House):** * Verified the outdoor coil is in fair and clean condition. * Tested and confirmed proper operation of the blower motor, condenser fan motor, compressor, compressor run capacitor, fan run capacitor, contactor, and electrical wiring. * Inspected and confirmed good condition of the blower wheel, primary drain pan, secured electrical wires, and ductwork. **System Performance:** * Measured a return air temperature of 73.0°F and a supply air temperature of 54.0°F. * Cleared the condensate drain line, cleaned out the primary pan, and tested the safety switch. **Additional Actions:** * Dusted the thermostat, checked the thermostat batteries, and tested thermostat operation. * Re


Aj S.

Aj S. Job Checkin

Today I arrived on site and performed a summer time maintenance on your HVAC equipment. **Indoor Unit (Package Unit):** * Verified the indoor unit is a package unit. * Confirmed the overall equipment condition is good. * Replaced the pleated 1" filter (18x24x1). * Observed the indoor coil is clean and in good condition. **Outdoor Unit (Package Unit):** * Verified the outdoor unit is a package unit. * Confirmed the outdoor coil is clean and in good condition, and cleaned it. **Electrical Components:** * Tested and confirmed proper operation of the blower motor, condenser fan motor, compressor, contactor, and electrical wiring. * Identified the compressor run capacitor and condenser fan motor run capacitor are not working properly or within specifications. **System Components:** * Inspected and confirmed the blower wheel, secondary drain pan, primary drain pan, electrical wires, and ductwork are in good condition and working properly. **System Testing & Adjustm


Brenden N.

Brenden N. Job Checkin

Today I performed a routine maintenance on your heat pump split system. I checked electrical connections on both the indoor and outdoor equipment, changed your air filters, flushed your drain line, checked the capacitor ratings, and then tested your system, and both heating and cooling mode. Your system is operating properly at this time.


Aidan D.

Aidan D. Job Checkin

Today, I arrived on site to perform winter maintenance on the HVAC equipment. Equipment Condition: * Overall condition is good. * Indoor unit located in the attic, functioning as an air handler for the whole home. * Outdoor unit is a heat pump situated on the side of the house. Filtration: * Checked and replaced pleated filters (20x20x5) today using customer-provided spare filters. Coil Condition: * Indoor coil is clean and in good condition. * Outdoor coil was cleaned today and is also in good condition. Electrical Components: * Tested and inspected various electrical components including blower motor, heat strip kit, condenser fan motor, compressor, and capacitors. * All components are working properly within manufacturer specifications. Inspections: * Blower wheel, electrical wires, primary and secondary drain pans are in good condition and functioning properly. * No components were found in poor condition. Temperature Readings: * Return air temperature measured at 73.0 degree


Brenden N.

Brenden N. Job Checkin

Today I performed a routine maintenance on your split system. I checked all electrical connections on both the indoor and outdoor equipment, flushed the drain line, changed the air filters, checked the capacitor ratings, and washed off the condenser outside. Your system is operating properly at this time.


Cody  W.

Cody W. Job Checkin

Today, I arrived on site and performed a summer time maintenance on your HVAC equipment. Here is a summary of my findings: Overall Equipment Condition: - Good Indoor Unit: - Location: Closet - Type: Air Handler - Picture: [Attach picture] Area Unit Services: - Whole house Filtration: - Pleated 1" - Replaced today Filter: - Size: 16x20x1 - Picture: [Attach picture] Condition of Indoor Coil: - Good - Clean Outdoor Unit: - Location: Side of House - Type: Heat Pump - Picture: [Attach picture] Condition of Outdoor Coil: - Good - Clean Tested and inspected electrical components: - Blower Motor - Condenser Fan Motor - Compressor - Compressor Run Capacitor - Fan Run Capacitor - Contactor - Electrical Wiring Inspected components in good condition and working properly: - Blower Wheel - Secondary Drain Pan - Primary Drain Pan - Electrical Wires Secured Tested and cleared condensate drain system: - Cleared Drain Line - Cleaned Out Primary Pan - Cleaned Out Secondary Pan - Tested Safety


Aidan D.

Aidan D. Job Checkin

Today, I arrived on site and performed a summer time maintenance on your HVAC equipment. Here is a summary of my findings: Overall Equipment Condition: - Good Location, Type, and Picture of Indoor Unit: - Package Unit, Mini Split Indoor Unit Area Unit Services: - Whole house, sun room Filtration: - Pleated 1" - Filter Size: 20x25x1 Condition of Indoor Coil: - Good, Clean - Brush Cleaned Today Location, Type, and Picture of Outdoor Unit: - Side of House, Package Unit, Mini Split Condenser Condition of Outdoor Coil: - Good, Clean - Cleaned Today Tested and inspected these electrical components on your equipment and they are working properly within manufacturers recommended specs and amperage's: - Blower Motor - Condenser Fan Motor - Compressor - Blower Run Capacitor - Compressor Run Capacitor - Fan Run Capacitor - Contactor - Electrical Wiring Tested these electrical components on your equipment and they are not working properly or not within manufacturers recommended specs and


Hunter C.

Hunter C. Job Checkin

I performed a winter time maintenance on your HVAC equipment. Today, I arrived on site and went to the site location where the indoor unit is located. The indoor unit is in the attic and it is an air handler. It services the upstairs area of your home. I replaced the Respicare filter today, and it is sized at 18x20. The indoor coil is in good condition and clean. Next, I went to the side of the house where the outdoor unit is located. It is a heat pump and the outdoor coil is also in good condition and clean. I cleaned it today. I tested and inspected several electrical components on your equipment, and they are all working properly within the manufacturers recommended specs and amperages. These components include the blower motor, heat strip kit, condenser fan motor, compressor, compressor run capacitor, fan run capacitor, contactor, and electrical wiring. There were no electrical components that were found to be not working properly or not within the manufacturers recommended specs a


Emonte  O.

Emonte O. Job Checkin

Today we performed a winter time tune up on your unit,everything is working properly at this time .Thank you for your business. Tallahassee FL


Ej O.

Ej O. Job Checkin

I completed a winter time maintenance on your HVAC equipment. Overall Equipment Condition: - Good Location, Type, and Picture of Indoor Unit: - Package Unit Area Unit Services: - Whole house Filtration: - Pleated 1" - Filter Size: 18x24x1 Condition of Indoor Coil: - Good, Clean Location, Type, and Picture of Outdoor Unit: - Side of House - Package Unit Condition of Outdoor Coil: - Good, Cleaned Today Tested and inspected these electrical components on your equipment and they are working properly within manufacturers recommended specs and amperages: - Heat Strip Kit - Condenser Fan Motor - Compressor - Compressor Run Capacitor - Fan Run Capacitor - Electrical Wiring - Electric Heat Strip Kit Safety's - Defrost Control Board - Contactor - Blower Motor Tested these electrical components on your equipment and they are not working properly or not within manufacturers recommended specs and amperages: - N/A Inspected these components on your system and they are in good condition an


Emonte  O.

Emonte O. Job Checkin

Charge is for labor only. Unit had a 10 year part warranty 11/28- replaced contactor via warranty, system operating properly at this time. Thank you for your business.


Phillip R.

Phillip R. Job Checkin

I performed a summer time tune up on three Goodman Air Conditioner units. Found the supply boots for the system located in the upstairs attic ended to be sealed. Estimate was approved via phone call. The office will be in touch to schedule the work Thank you for your business View visual findings from this job here - https://visionshare.xoi.io/?id=XA-EFFC-6BD19B7B5D1043A18D9BB43DD39B3F49